5–94CLI Commands

CAUTION: Setting CACHE_UPS without having a UPS or similar backup system in place may result in data loss if power is interrupted.

Specify NOCACHE_UPS to instruct the controller to perform regular cache battery checks and evaluate the condition of the cache batteries.

Setting the CACHE_UPS switch for either controller sets the CACHE_UPS switch for both controllers.

COMMAND_CONSOLE_LUN

NOCOMMAND_CONSOLE_LUN (Default)

Enable or disables the virtual LUN used with the StorageWorks Command Console. When changed, the new setting for this switch takes effect immediately.

NOTE: This switch enables (COMMAND_CONSOLE_LUN) and disables (NOCOMMAND_CONSOLE_LUN) the CCL in SCSI-2 mode only. This switch has no effect in SCSI-3 mode.

Select COMMAND_CONSOLE_LUN to enable the virtual LUN. Select

NOCOMMAND_CONSOLE_LUN to disable the virtual LUN.

HOST_FUNCTION=mode

HOST_FUNCTION=(ID,mode)

Configures the host compatibility mode for a controller target ID number. When changed, you must restart both controllers in order for the new setting to take effect.

Select the HOST_FUNCTION=mode switch to set all of the targets on the host interface to the same mode. The default mode is A.

Select the HOST_FUNCTION=(ID,mode) switch to configure the host port on a target-by-target basis for compatibility with various operating systems.

Page 280
Image 280
Compaq HSZ80 manual 94CLI Commands, Commandconsolelun, Nocommandconsolelun Default, HOSTFUNCTION=mode HOSTFUNCTION=ID,mode