5–7

ADD DISK

Names a disk drive and adds it to the controller’s configuration.

NOTE: The controller supports a maximum of 72 storage devices, even though more than 72 target IDs are available. Do not exceed the maximum number of devices in the subsystem.

Syntax

ADD DISK container-name scsi-port-target-lun

Parameters

container-name

Assigns a name to the disk device. This is the name used with the ADD UNIT command to create a single-disk unit.

The disk name must start with a letter (A through Z) and may consist of a maximum of nine characters including letters A through Z, numbers 0 through 9, periods (.), dashes (-), or underscores (_).

IMPORTANT: It is common to name a disk drive DISKpttll, where pttll is the disk’s Port-Target-LUN address. Although other naming conventions are accept- able, this one presents the user with the type of disk drive and its SCSI location.

scsi-port-target-lun

Indicates the SCSI device PTL address. Place one space between the port number, target number, and the two-digit LUN number when entering the PTL address. See the “Device PTL Addressing Convention within the Controller,” page 3–36,for an explanation of the PTL addressing naming format.

NOTE: See the HSZ80 Array Controller ACS Version 8.3 Release Notes to determine whether the disk drive you are planning to use is compatible with the controller.

Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide

Page 193
Image 193
Compaq HSZ80 manual ADD Disk, Syntax, Parameters