2–23

Set the maximum data-transfer rate

Use the following command:

SET THIS_CONTROLLER PORT_1_TRANSFER_RATE_REQUESTED = speed

or

SET THIS_CONTROLLER PORT_2_TRANSFER_RATE_REQUESTED = speed

If you are configuring dual-redundant controllers, also set the transfer rate for the other controller. However, if you are running more than one HSZ80 SCSI host port on the same bus, you must set their transfer rates to be identical. Use the following command:

SET OTHER CONTROLLER PORT_1_TRANSFER_RATE_REQUESTED=speed

or

SET OTHER CONTROLLER PORT_2_TRANSFER_RATE_REQUESTED=speed

See Chapter 5, “CLI Commands,” for more information about setting the data transfer rate.

Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide

Page 77
Image 77
Compaq HSZ80 manual Set the maximum data-transfer rate