5–91

SET controller

Changes parameters on the specified controller.

Syntax

SET controller

Parameter

controller

Indicates which controller is to be set. Specify OTHER_CONTROLLER or

THIS_CONTROLLER.

Switches

Table 5–5lists the switches available with this command. Descriptions of the switches follow the table.

Table 5–5 SET controller Switches

Switch

Values

 

 

ALLOCATION_CLASS

0–4294967295

 

In DIGITAL Open VMS do not specify a

 

number over 65535

 

 

CACHE_FLUSH_TIMER

1–65535 sec, 10 (default)

 

 

CACHE_UPS

None

NOCACHE_UPS

 

 

 

COMMAND_CONSOLE_LUN

None

NOCOMMAND_CONSOLE_LUN

 

 

 

HOST_FUNCTION

A, B, C, D, E, F

 

 

NODE_ID

assigned during manufacturing

 

 

Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide