5–141

DT_SUPPORT

State:

RECONSTRUCTING

LOCAL DISK100 (member 0) is NORMAL

REMOTE DISK200 (member 1) is NORMALIZING 2% complete

LOCAL DISK300 (member 2) is NORMALIZING 0% complete

REMOTE DISK400 (member 3) is NORMALIZING 0% complete

Size: 8378028 blocks

This example shows the full information for a controller:

SHOW THIS_CONTROLLER FULL

Controller:

Not configured for dual-redundancy Device port SCSI address 7

Time: NOT SET Host port:

SCSI target(s) (0, 2, 4, 5) Preferred target(s) (0, 2, 4)

TRANSFER_RATE_REQUESTED = 20MHZ Host Functionality Mode = A Command Console LUN is target 0, lun 4

Cache:

64 megabyte write cache, version 4 Cache is GOOD

Battery is GOOD

No unflushed data in cache

CACHE_FLUSH_TIMER = DEFAULT (10 seconds)

NOCACHE_UPS Mirrored Cache:

64 megabyte write cache, version 4 Cache is GOOD

Battery is GOOD

No unflushed data in cache Extended information:

Terminal speed 19200 baud, eight bit, no parity, 1 stop bit Operation control: 00000001 Security state code: 75580 Configuration backup disabled

Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide

Page 327
Image 327
Compaq HSZ80 manual 141, Show Thiscontroller Full