Compaq HSZ80 manual SET Nofailover, 120CLI Commands, Destroyunflushabledata

Models: HSZ80

1 386
Download 386 pages 41 Kb
Page 306
Image 306

5–120CLI Commands

SET NOFAILOVER

Reconfigures both controllers to operate in a nondual-redundant (nonfailover) configuration. Immediately after entering this command, remove one controller from the shelf because the sharing of devices is not supported by nonredundant controllers.

NOTE: SET NOFAILOVER and SET NOMULTIBUS_FAILOVER have the same effect. Either command exits from transparent or multiple bus failover mode.

It is recommended that both controllers be present when this command is carried out. Otherwise, the controllers become misconfigured with each other, requiring additional steps later to allow the “other controller” to be configured for failover.

This command affects both controllers, regardless of the controller on which the command is carried out. All units accessed through the “other controller” failover to “this controller” and the “other controller” is shut down. No configuration information is lost when the SET NOFAILOVER command is carried out.

Syntax

SET NOFAILOVER

Switches

DESTROY_UNFLUSHABLE_DATA

NODESTROY_UNFLUSHABLE_DATA (Default)

Instructs the controller how to handle unflushable data contained within the write- back cache. Unflushable data may be present if, for example, a member of a stripeset has failed. If the other controller is not running, use this switch to specify how to handle this unflushable data when taking the controller pair out of failover mode. If the other controller is running, unflushable data must be cleared from the other controller with the CLI command, CLEAR_ERRORS controller INVALID_CACHE, 5–36.

Page 306
Image 306
Compaq HSZ80 manual SET Nofailover, 120CLI Commands, Destroyunflushabledata, Nodestroyunflushabledata Default