4–13

ADD UNIT D1 RAID1 PARTITION=1

ADD UNIT D2 RAID1 PARTITION=2

ADD UNIT D3 RAID1 PARTITION=3

ADD UNIT D4 RAID1 PARTITION=4

SHOW RAID1

.

.

.

Partition number

Size

 

Starting Block

Used by

1

1915

(0.98

0

D1

 

MB)

 

 

 

2

1915

(0.98

1920

D2

 

MB)

 

 

 

3

1915

(0.98

3840

D3

 

MB)

 

 

 

4

2371

(1.21

5760

D4

MB)

.

.

.

Adding a Disk Drive to the Spareset

The spareset is a collection of hot spares that are available to the controller should it need to replace a failed member of a RAIDset or mirrorset.

Use the following steps to add a disk drive to the spareset. This procedure assumes that the disks that you are adding to the spareset have already been added to the controller’s list of eligible devices.

1.Add the disk drive to the controller’s spareset list. Use the following syntax:

ADD SPARESET DISK nnnn

Repeat this step for each disk drive you want to add to the spareset.

Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide

Page 161
Image 161
Compaq HSZ80 manual Adding a Disk Drive to the Spareset