Frame Relay Configuration 6-9

Full Status Enquiry Counter specifies the number of standard status enquiries to exchange before issuing a full status inquiry from the network. The value ranges from 1 to 255 with a factory default of 6 enquiries. A full status enquiry response from the network updates the Frame Relay network and link information tables.

Error Threshold Counter specifies the maximum number of error events detected within the most recent monitored events (specified by the Monitored Event Counter parameter). If this counter is exceeded, an alarm is generated.

The counter must be less than or equal to the Monitored Event Counter. The value ranges from 1 to 10 with an LMI factory default of 3 events and an Annex D factory default of 3 events.

Monitored Event Counter specifies the number of most recent consecutive exchanges to be monitored by the router. The values ranges from 1 to 10, with a factory default of 4 events.

Status Polling Timer specifies the number of seconds between consecutive status enquiries initiated by the router to the network. At the specified time interval, the router requests a sequence number exchange status. If the router does not receive a status message response within the specified polling time, an error is detected.

The value ranges from 5 to 30, with an LMI factory default of 10 seconds and an Annex D factory default of 10 seconds.

After completing all the Frame Relay parameter modifications, press <Esc> and select Yes to save the changes to the network interface configuration.

The Network Interfaces screen will be displayed showing the port as enabled. Press <Esc> to return to the Internetworking Configuration menu and continue with the following sections.

Page 86
Image 86
Emulex DCP_link manual Frame Relay Configuration