†When removing "Housing, Middle", the grounding spring may detach and drop from "Main Board Unit". If this occurs, reattach it to its original position referring to the following figure.

Grounding

Spring

Figure 2-7. Reattaching the Ground Spring

†Make sure to mount "Panel FFC" passing under the hooks as shown in the figure and then secure "Panel FFC" with a two- sided tape.

†Make sure that "Panel FFC" is securely set and it is not reaching the upper edge of the rib of "Housing, Middle" as shown in the figure.

†Make sure that the connector cable of "Power Supply Board" is securely set in the groove of "Housing, Lower".

Groove

 

Connector Cable

Figure 2-9. Mounting the Connector Cable

†Make sure that "Panel FFC" is not stuck under "Housing, Middle".

†Make sure to tighten up the screws on the back of "Housing, Middle" in the order as shown in the figure.

Rib

Keep some clearance here.

Figure 2-8. Mounting "Panel FFC"