†Reinstalling "Paper Guide, Front"

„Make sure that the dowels and the hook of "Paper Guide, Front" are correctly secured to "Frame, Main".

Dowels

Hook

Figure 2-57. Reinstalling "Paper Guide, Front"

„Make sure that the tabs of "Porous Pad, Paper Guide, Front, Left" and "Porous Pad, Paper Guide, Front, Support" are facing straight to downward through the slots of "Paper Guide, Front".

„Make sure that there is no gap between "Paper Guide, Front" and "Frame, Main".

„If any ink leaks on the rib of "Paper Guide, Front", clean it with a cotton swab. (At this time, take care not to touch "Porous Pad, Paper Guide, Front" of "Paper Guide, Front" with the cotton swab.)

†Reinstalling "Roller EJ Assy."

„Make sure that both left and right "Bushing, 5" are correctly secured.

„Make sure that "Grounding Spring, EJ Left (Right)" is correctly attached to the both ends of "Roller EJ Assy.".

„When installing "PF Timing Belt", do not damage the teeth of "Spur Gear, 41.48".

„Make sure that "Roller EJ Assy." moves smoothly.

ADJUSTMENT † When replacing "Roller EJ Assy.", apply G-26 grease in the

REQUIRED

adequate dose to the specified points.

†When removing or replacing "PF Timing Belt", implement the tension adjustment with the digital tension gauge.

†When having removed or replaced "Paper Guide, Front", implement the following adjustment. (Refer to Chapter 3 "ADJUSTMENT")

1.First Dot Adjustment

2.PW Sensor Adjustment

3.Head Angular Adjustment

4.Bi-D Adjustment