Stylus Photo R300/R310

Revision A

2.3.11 Removing APG Assy.

†External View

Hook

Tab

CN7

Screwing Tab

APG Assy.

Acetate Tape

†Parts/Units which should be removed before removing "APG Assy." Paper Support Assy./Housing, Upper/Housing, Middle

†Procedure for Removing

1.Disconnect the connector cable of "PG Motor" from CN7 of "Main Board".

2.Release the connector cables of "PF Motor" and "PG Motor" from the following points.

„Acetate tape

„Hook of "ASF Assy."

„Tab of "Paper Guide, CDR" (x2)

„Screwing tab of "Housing, Lower"

3.Remove the screw which secures "APG Assy.". Then, remove "APG Assy.".

„ Make sure that the hooks (x2) and the dowels (x2) of "APG

Assy." are securely attached to "Frame, Main".

„Check if the part indicated in the following figure is inserted in the slits of "Frame, Main".

C.B.S 3x6 (6-8kgf•cm)

Figure 2-26. Removing "APG Assy."

It has to be inserted in the slit of "Frame, Main"

Dowel

Hook

APG Assy.

Figure 2-27. Reinstalling "APG Assy."

DISASSEMBLY AND ASSEMBLY

Disassembly

55

Page 55
Image 55
Epson R310 service manual Removing APG Assy