SETTING CONFIGURATION OPTIONS

Loop option. The Loop option determines what the autoloader does after it has finished processing the last cartridge in the sequence. The autoloader can either loop back to the first cartridge in the sequence and start processing the cartridges again (Loop option ON) or stop and wait for operator intervention (Loop option OFF). Operator intervention typically means removing cartridges for storage and inserting new cartridges.

Random is the default operating mode for the autoloader. To change the operating mode to Sequential and set the Restart and Loop options:

1.At the Home screen, press , , , or to access the main menus. If necessary, enter the operator panel password (see page 42).

2.Press or until the Configuration menu appears:

C h a n g e a

C o n f i g u r a t i o n

3.Press to see the menu selections.

4.Press or until the following screen appears.

 

 

 

C

h a n g e

O

p .

M o d e ?

 

 

 

 

N

o w

R a n

d

o m

 

 

 

 

 

 

 

 

5.

Press

to display the operating mode selection screen:

 

 

 

 

 

 

 

 

 

 

S

e l e c t

O p .

M o d e

 

 

 

 

R

a n d o m

M o d

e

 

 

 

 

 

 

 

 

6.

Press

or

to switch between Random Mode and Sequential Mode.

7.

Press

to select the new value. If you selected Sequential Mode, skip to

 

step 8. If you selected Random mode, a confirmation message appears:

 

 

 

 

 

 

 

 

 

 

 

 

 

S

e t

O p .

 

M o

d e

t o

 

 

 

 

R

a n d o m

n

o w

?

 

 

 

 

 

 

 

 

 

a. Press

 

to enact the change (or

if you don’t want to make the

 

change).

 

 

 

 

 

 

 

b. Skip to step 9.