CHAPTER 7—MAINTENANCE

PREPARING FOR REPLACEMENT

Note: If your autoloader is installed in a rack, it is not necessary to remove the autoloader from the rack to replace the tape drive. It is also not necessary to disconnect the SCSI cable, terminator, or Ethernet cable from the back of the autoloader as long as they do not interfere with your access to the tape drive.

To prepare for replacement:

1.Obtain these tools: a #1 Phillips screwdriver, a #2 Phillips screwdriver, and a small flat-blade screwdriver.

2.Ensure that the environment is free of conditions that could cause electrostatic discharge (ESD). If possible, use an antistatic mat and a grounded static protection wristband during installation. If a mat and wristband are not available, touch a known grounded surface, such as a computer’s metal chassis.

3.Power off the autoloader (press the 0 on the back of the autoloader) and disconnect the power cord.

Warning

Before performing any installation or maintenance procedures, be sure that the

 

autoloader’s power switch is off and that the power cord is disconnected from the

 

autoloader and the outlet.

 

 

 

 

Warnung Vor der Ausführung von Installations- oder Wartungsarbeiten ist darauf zu achten, daß der Autoloader-Netzschalter auf “Aus” gestellt ist und daß das Anschlußkabel vom Autoloader und der Steckdose entfernt ist.

Advertencia Antes de realizar cualquier procedimiento de instalación o de mantenimiento, comprobar que el interruptor de alimentación de la biblioteca está apagado y que el cable de alimentación no está enchufado ni a la biblioteca ni a la toma de corriente.

92

 

PRODUCT MANUAL

1012581

 

 

 

 

 

 

 

Page 108
Image 108
Exabyte 1X7 LTO manual Preparing for Replacement, Autoloader and the outlet