CHAPTER 8—TROUBLESHOOTING

Hardware operation. You can verify that the autoloader hardware is operating using the following methods:

Use the autoloader’s Diagnostics menu (under Demo Mode) to move cartridges from random cells in and out of the tape drive. See page 75 for instructions.

Use the autoloader’s Command menu to import or export cartridges, and to move specific cartridges into and out of the tape drive. See page 64 for instructions.

Use LibTool to display the current inventory of cartridges, and to move cartridges into and out of the tape drive. Refer to the program’s online help for instructions on performing upgrades and diagnostics

LibTool is available as a free download from

www.exabyte.com/downloads.

If the autoloader reports an error during any of these tests, use LibTool to obtain a diagnostic log from the autoloader immediately after the error is reported (see page 102). Alternatively, if your autoloader is equipped with the optional Ethernet port, you can use FTP to obtain a diagnostic log from the autoloader (see page 100). Exabyte Technical Support can examine the log to determine the nature of the reported error.

Hardware servo error. If your autoloader is reporting a hardware servo error, check the following:

Make sure that the autoloader is either installed in a rack or is resting on a hard, flat surface.

Make sure that there is nothing resting or pressing on the top of the autoloader.

Make sure that the autoloader is not oriented on its side.

Make sure that the autoloader has the latest version of firmware installed. Firmware upgrade instructions begin on page 100.

Make sure that the cartridge carousel can turn smoothly, as follows:

1.Power off the autoloader and manually open the door (see page 67 for instructions).

2.Insert your hand through the door and gently turn the carousel in either direction to turn it.

3.If the carousel does not turn, remove the tape drive from the autoloader (see page 93) to determine if there is a cartridge extending from the tape drive and blocking the rotation of the carousel. Remove the cartridge and reinstall the tape drive.

106

 

PRODUCT MANUAL

1012581

 

 

 

 

 

 

 

Page 122
Image 122
Exabyte 1X7 LTO manual 106