showhardconf(8)
396 SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised April 2010
EXTENDED
DESCRIPTION
■When the configuration and status information regarding FRUs and domain
information are displayed, for any failed or degraded unit, an asterisk (*)
indicating an abnormal unit is displayed along with any of the following states:
■On the Type field of the memories, the number indicates the DIMM size and the
alphabet, A or B, indicates the DIMM rank.
EXAMPLES EXAMPLE 1 Displays the information of the FRUs in the M5000 server.
Status Description
Faulted The component is faulty and is not operating
Degraded The component is operating. However, either an error has been
detected or the component is faulty. As a result, the component
might be operating with reduced functionality or performance.
Deconfigured As a result of another component's faulted or degraded status,
the component is not operating. (The component itself is not
faulted or degraded.)
Maintenance The component is under maintenance. A deletefru(8),
replacefru(8), or addfru(8) operation is currently underway
Normal It is operating normally.
Example Description
Type: 1A 1 GB, rank 1
Type: 2A 2 GB, rank 1
Type: 2B 2 GB, rank 2
XSCF> showhardconf
SPARC Enterprise M5000;
+ Serial:BCF07500B6; Operator_Panel_Switch:Locked;
+ Power_Supply_System:Dual; SCF-ID:XSCF#0;
+ System_Power:On; System_Phase:Cabinet Power On;
Domain#0 Domain_Status:Initialization Phase;
Domain#1 Domain_Status:Initialization Phase;
MBU_B Status:Normal; Ver:0201h; Serial:BC07490823 ;
+ FRU-Part-Number:CF00541-0478 05 /541-0478-05 ;
+ Memory_Size:64 GB;