cfgdevice(8)
30 SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised September 2008
Privileges You must have platadm or fieldeng privileges to run this command.
Refer to setprivileges(8) for more information.
OPTIONS The following options are supported:
EXTENDED
DESCRIPTION
When the command is executed, a prompt to confirm execution of the command
with the specified options is displayed. Enter "y" to execute the command or "n"
to cancel the command.
SAS-status Connection status between I/O unit and the system.
enable/disable: Connection setting between I/O unit and
the system. When starting a domain with no I/O unit, the
"disable" may be displayed.
enable: Yes
disable: No
up/down: Logical connection between I/O unit and the
system.
up: Connected.
down: Not connected.
-c attach Connects the CD-RW/DVD-RW drive unit and the tape drive
unit to the specified port.
-c detach Disconnects the CD-RW/DVD-RW drive unit and the tape
drive unit from the specified port.
-h Displays usage statement. When used with other options or
operands, an error occurs.
-l Displays the current status of the CD-RW/DVD-RW drive
unit and the tape drive unit currently set up.
-M Displays text by page. This option provides a function that is
the same as that of the more command.
-n Automatically answers "n" (no) to all prompts.
-p port_no Specifies the number of the port, in the specified domain, to
which the CD-RW/DVD-RW drive unit and the tape drive
unit is to be connected. port_no can be specified in the ’IOU
number-PCI slot number’ format. The -p option cannot be
omitted.
-q Suppresses all messages to stdout, including prompts.
-y Automatically answers "y" (yes) to all prompts.