testsb(8)
510 SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised September 2008
OPTIONS The following options are supported:.
OPERANDS The following operand is supported:
EXTENDED
DESCRIPTION
■When the command is executed, a prompt to confirm execution of the command
with the specified options is displayed. Enter "y" to execute the command or "n"
to cancel the command.
■When the system board (XSB) belonging to the specified PSB is in any status
below, the testsb(8) command results in an error.
■XSB is installed in the domain and this domain is in operation.
-c {all|expansion} Specifies the target PSB to be diagnosed. One of the values
shown below can be specified:
all Diagnoses all the PSB that are mounted.
If the following conditions not satisfied, it leads to an error.
■The system has been powered off.
■All of the target PSB are Uni-XSB.
expansion Diagnoses all the PSB that are mounted
on the expansion cabinet.
If the following conditions not satisfied, it leads to an error.
■All of the target PSB are not operating on the domain.
■All of the target PSB are Uni-XSB.
-h Displays usage statement. When used with other options or
operands, an error occurs.
-m diag=mode Specifies the diagnostic level of initial diagnosis. One of the
values shown below can be specified:
min Normal (default)
max Maximum
-n Automatically answers "n" (no) to all prompts.
-q Suppresses all messages to stdout, including prompts.
-v Displays a detailed message of initial diagnosis.
-y Automatically answers "y" (yes) to all prompts.
location Specifies only one PSB number. An integer from 00–15 can be
specified.