cfgdevice(8)
System Administration 31
■If connection or disconnection is made when the power supply of the system is
ON, settings are made immediately after cfgdevice(8) command execution.
When the power supply of the system is OFF, connection or disconnection is
reserved and settings are made after the power supply is turned on.
■The CD-RW/DVD-RW and the tape connection is maintained even if the domain
configuration is changed, or a CPU/Memory Board unit (CMU) or I/O unit
(IOU) is replaced with a connected CD-RW/DVD-RW drive unit and the tape
drive unit.
■The CD-RW/DVD-RW and the tape connection is maintained even if the domain
power is turned off or the system is rebooted.
■The CD-RW/DVD-RW drive unit and the tape drive unit is mounted in each of
the base and expansion cabinets in the M9000 server that has the expansion
cabinet. In such cases, each CD-RW/DVD-RW drive unit and the tape drive unit
can be connected only to a domain within the cabinet in which the drive is
mounted. Settings for connection must be made for both the base cabinet and
expansion cabinet.
XSCF> cfgdevice -l
Current connection for DVD/DAT:
Main chassis: port 0-0
Expansion chassis: port 8-0
Expander status
Port No. IOU/SAS-status SAS-status
-----------------------------------
0-0 enable up enable up
0-2 disable down enable up
0-4 disable down enable up
0-6 disable down enable up
1-0 disable down enable up
1-2 disable down enable up
1-4 disable down enable up
1-6 disable down enable up
2-0 disable down enable up
2-2 disable down enable up
2-4 disable down enable up
2-6 disable down enable up
8-0 enable up enable up