shownetwork(8)
448 SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised February 2010
OPERANDS The following operands are supported:
EXTENDED
DESCRIPTION
■In the M8000/M9000 servers, a takeover IP address can be used without a need
to determine whether XSCF has been switched. By setting the LAN ports of the
active XSCF unit as lan#0 and lan#1, they can be accessed with the names
lan#0 and lan#1.
■In the M3000/M4000/M5000 servers, the value of the lan#0 is fixed with
xscf#0-lan#0, and the lan#1 is fixed with xscf#0-lan#1.
interface Specifies the network interface whose information is to be
displayed. One of the following values can be specified,
depending on the system configuration. If this operand is
specified with the -a option, the operand is ignored.
■In the M3000/M4000/M5000 servers:
For XSCF unit 0 :
xscf#0-lan#0 XSCF-LAN#0
xscf#0-lan#1 XSCF-LAN#1
For abbreviation:
lan#0 an abbreviation of XSCF-LAN#0
lan#1 an abbreviation of XSCF-LAN#1
■In the M8000/M9000 servers:
For XSCF unit 0 :
xscf#0-lan#0 XSCF-LAN#0
xscf#0-lan#1 XSCF-LAN#1
xscf#0-if Interface between XSCF units (Inter SCF
Network; ISN)
For XSCF unit 1:
xscf#1-lan#0 XSCF-LAN#0
xscf#1-lan#1 XSCF-LAN#1
xscf#1-if ISN
For takeover IP address:
lan#0 takeover IP address for XSCF-LAN#0
lan#1 takeover IP address for XSCF-LAN#1