Manuals
/
Honeywell
/
Computer Equipment
/
Scanner
Honeywell
2700
manual
Models:
2700
1
276
278
278
Download
278 pages
39.75 Kb
271
272
273
274
275
276
277
278
Specification
Install
Error codes
Depth of Field Charts
Setting Custom Defaults
Bar Code Scanning Delays
Symbologies
Audible and Visual Indicators
Connecting EAS
Dimension
Page 276
Image 276
Page 275
Page 277
Page 276
Image 276
Page 275
Page 277
Contents
Stratos
Disclaimer
Product Agency Compliance
Canada
Europe
Australia/NZ
Japan
Russia
South Korea
Required Safety Labels
Patents Solids and Water Protection
Laser LIGHT, do not Stare Into BEAM, Class 1 Laser Product
Page
Table of Contents
Programming the Bioptic Scanner Interface
USB HID
Input/Output Settings
NCR ACK/NAK
Programming an Auxiliary Scanner
Scale
Symbologies
Data Editing
Data Formatting
UPC-A UPC-A/EAN-13
EAS Settings
Serial Programming Commands
Interface Keys
Utilities
Product Specifications
Maintenance
Appendix a Reference Charts
Appendix B Auxiliary Honeywell Scanner Configuration Codes
Dimensions Site Requirements
Getting Started
About This Manual
Printing Single Bar Codes
Configuring
Power Installation
Power from Host
Unpacking Your Device
Features of the Stratos Bioptic
Audible and Visual Indicators
Push Button Functionality
Scale Zero
Image Capture
Sound
LCD Diagnostic Display
LCD Diagnostic Display
LCD Video Display
Reading Techniques
Page
Installation
Installation Diagrams
Stratos 2751 Product Dimensions
Stratos 2751 Installation Dimensions
Stratos 2752 Product Dimensions
Stratos 2752 Installation Dimensions
Leveling Feet See Bottom View
Stratos 2753 Product Dimensions
Stratos 2753 2 Point Installation Dimensions
38.1mm 750 19.05mm 367 33mm
Stratos 2753 3 Point Installation Dimensions
Installing the Stratos Bioptic
Stratos 2753 Bottom View
Device Ports
Left Side Ports
Placing the Stratos Bioptic in the Check Stand
Alternate Lift Method
Adjust the Height
Place the Platter
Scale out of calibration
Leveling
Ideal Good Not Level If not rocking
Connecting an LCD Video Display
Pole Display if included
Connecting EAS
Connecting to the POS System
Checkpoint EAS Antenna Port Sensormatic Connectors
Checkpoint
Page
Page
Menu Bar Code Security Settings
Setting Custom Defaults
Programming the Bioptic Scanner Interface
Introduction
Resetting the Custom Defaults
Programming the Scanner Interface Plug and Play
RS232 Serial Port Interface
RS232 Opos Scanner Only Dual Cable
USB Interface
USB PC or Macintosh Keyboard
USB Serial Commands
USB Serial Emulation
USB Host Power
ACK/NAK Mode
CTS/RTS Emulation
Symbology Suffix
Host System Plug and Play Codes
RS485
RS485 Packet Mode
IBM 46XX Scanner Only
IBM Port 17 Interface Scanner Only
RS485 Packet Length
USB IBM SurePos
NCR Host System Scanner Only Dual Cable
Verifone Ruby Terminal Default Settings
Gilbarco Terminal Default Settings
Wincor Nixdorf Terminal Default Settings
Symbology Prefix
Wincor Nixdorf Beetle Terminal Default Settings
Keyboard Country Layout
Keyboard Countries
UPC-A
Keyboard Countries
Keyboard Countries
Keyboard Countries
Keyboard Countries
Keyboard Countries
Keyboard Countries
SCS
Keyboard Countries
Keyboard Countries
Keyboard Style
Keyboard Conversion
Shift Lock
Default = Control + X Mode Off
Keyboard Modifiers
Numeric Keypad Mode On Numeric Keypad Mode Off
RS232 Baud Rate
RS232 Word Length Data Bits, Stop Bits, and Parity
Page
RS232 Receiver Timeout
RS232 Handshaking
Page
RS232 Timeout
Host Communications Timeout Beeper
Host NAK Retries in ACK/NAK Mode
Host Timeout Retries in ACK/NAK Mode
Communication Timeout Beeper
Timeout Retries
NAK Retries
Support BEL/CAN in ACK/NAK
RS232 Defaults
NCR Scanner Only Mode
NCR Modifiers
NCR Modes
NCR Scanner Scale Mode
NCR Special Function Mode
NCR Scanner Scale Acknowledgment
NCR NOF Not-on-File Error
Block Check Character
NCR Prefix
NCR Suffix
Do Not Wait for NCR Weight
NCR Weight Timeout
NCR NOF Not-on-File Number of Beeps
Timeout
Input/Output Settings
Power Up Settings
Power Save Mode
Wake Activation
Power Save Mode Timeout
Laser Idle/Sleep State
Motor Idle/Sleep State
Power Up Beeper
Button Controls
Button Click
F1 Programmable Button
Volume Adjustment
Sound Button
Last Scan Repeat
EAS Function
Frequency Adjustment
Sleep Mode
Sound Lock
Error Condition
Image Capture Button
Customer Imager Control
Cashier Imager
Good Read Indicators
Beep on BEL Character
Beeper Good Read
Beeper Volume Good Read
Beeper Transmit Order
Beeper Pitch Good Read
Beeper Duration Good Read
Number of Beeps Good Read
Error Indicators
Beeper Pitch Error
Number of Beeps/LED Flashes Error
Beep on EAS Deactivation
LED Settings
Bar Code Scanning Delays
Disabled Scanner LED Flash
Reread Delay
User-Specified Reread Delay
2D Reread Delay
Same Symbol Test
Bar Code Absence Detection
Character Activation Mode
Activation Character
End Character Activation After Good Read
Character Deactivation Mode
Character Activation Laser Timeout
Output Sequence Overview
Deactivation Character
Output Sequence Editor
To Add an Output Sequence
Other Programming Selections
Output Sequence Example
Sequence Timeout
SEQBLK62001241FF6A001342FF69001243FF
Sequence Match Beeper
Partial Sequence
Default = Off
No Read
Scanner-Bioptic Packet Mode
Communication Timeout
Programming an Auxiliary Scanner
Scanner to Bioptic Communication
Aux Port Configuration Codes
Good Read Beep Aux Scanner
Aux Scanner D/E Commands
Reread Delay Override
Page
Scale
Programming the Scale Interface
RS232
Opos Single Cable
POS Beep on Send Weight
IBM 3rd Generation 46xx Single Cable
IBM OEM USB Single Cable
Scale Status Bytes
Scale Type
Scale Calibration
Tools Required
Priming the Scale for Calibration
Putting the Scale into Service Mode
Scale Calibration
Scale Calibration with Remote Display
Group 2 bld Weight Unit Ranges
Step
Scale Calibration without Remote Display
Fulcap
Page
Scale Calibration with Push Buttons
Single Rangle LBS
Calibration Verification
Increasing Load Test
Shift Test
Decreasing Load Test
00 lbs 00kg
15.01 lbs 7.505kg
Security Seal Installation
Wire Security Seal
Return to Zero Test
Pressure Sensitive Security Seal
Page
Page
Scan the Add Prefix or Add Suffix symbol
Data Editing
Prefix/Suffix Overview
Points to Keep In Mind
Example Add a Tab Suffix to All Symbologies
To Add a Carriage Return Suffix to All Symbologies
Prefix Selections
To Clear One or All Prefixes or Suffixes
Suffix Selections
Cash Register Code IDs
Function Code Transmit
Communication Check Character
Intercharacter, Interfunction, and Intermessage Delays
Intercharacter Delay
User Specified Intercharacter Delay
Interfunction Delay
Intermessage Delay
Data Formatting
Data Format Editor Introduction
Add a Data Format
Terminal Type
Editor Commands
Clear One Data Format
Clear all Data Formats
Data Format Editor Commands
Send Commands
Terminal ID Table
Send all characters
Send all characters up to a particular character
Send all characters up to a string
Send all but the last characters
Insert a character multiple times
Insert symbology name
Insert a string
Insert bar code length
Move Commands
Insert key strokes
Move the cursor forward a number of characters
Search Commands
Move the cursor backward a number of characters
Move the cursor to the beginning
Move the cursor to the end
Search backward for a character
Search forward for a string
Search backward for a string
Search forward for a non-matching character
Miscellaneous Commands
Search backward for a non-matching character
Suppress characters
Stop suppressing characters
Stop replacing characters
Compare characters
Compare string
Check for a number
Insert a delay
Data Formatter
Discard Data
Data Format Non-Match Error Tone
Primary/Alternate Data Formats
Single Scan Data Format Change
Page
Symbologies
All Symbologies
Message Length Description
Codabar
Codabar On/Off
Codabar Start/Stop Characters
Codabar Check Character
Codabar Concatenation
Codabar Redundancy
Codabar Message Length
Code
Code 39 On/Off
Code 39 Start/Stop Characters
Code 39 Check Character
Code 39 Message Length
Code 39 Redundancy
Code 32 Pharmaceutical Paraf
Paraf
Full Ascii
Code 39 Code
Interleaved 2
Interleaved 2 of 5 On/Off
Null Characters
Check Digit
Interleaved 2 of 5 Redundancy
Interleaved 2 of 5 Message Length
NEC 2
NEC 2 of 5 On/Off
NEC 2 of 5 Redundancy
NEC 2 of 5 Message Length
Code 93 On/Off
Code 93 Redundancy
Code 93 Message Length
Code 93 Code
Straight 2 of 5 Industrial three-bar start/stop
Straight 2 of 5 Industrial On/Off
Straight 2 of 5 Industrial Redundancy
Straight 2 of 5 Industrial Message Length
Straight 2 of 5 Iata two-bar start/stop
Straight 2 of 5 Iata On/Off
Straight 2 of 5 Iata Redundancy
Straight 2 of 5 Iata Message Length
Matrix 2
Matrix 2 of 5 On/Off
Matrix 2 of 5 Redundancy
Matrix 2 of 5 Message Length
Code 11 On/Off
Check Digits Required
Check Digit Validation
Code 11 Redundancy
Code 11 Message Length
Code 128 On/Off
Group Separator Output
Code 128 Redundancy
Isbt
Code 128 Message Length
Code 128 Code
Concatenation Timeout
Isbt 128 Predefined Concatenation Sequences
Isbt 128 Predefined Concatenation Sequences On/Off
Isbt 128 User-Defined Concatenation Sequences
Isbt 128 User-Defined Concatenation Sequences On/Off
Content Verification
Transmit Identifiers
Flag Digit Conversion
Included, scan Transmit With Identifiers. Default = Off
GS1-128
GS1-128 On/Off
GS1-128 Application Identifier Parsing
GS1-128 Message Length
Telepen
Telepen On/Off
Telepen Output
Telepen Redundancy
Telepen Message Length
UPC-A On/Off
UPC-A Check Digit
UPC-A Number System
UPC-A Addenda
UPC-A Addenda Required
UPC-A Addenda Separator
UPC-A Redundancy
UPC-A/EAN Addenda Redundancy
With Extended Coupon Code
UPC-A Number System 4 Addenda Required
Default = Don’t Require Coupon Code/Addenda
UPC-A Number System 5 Addenda Required
Addenda Timeout
Coupon GS1 DataBar Output
In-Store Printed Bar Codes
Stitching
Framing
UPC/EAN Security
Redundancy
UPC-E0 On/Off
UPC-E0 Expand
UPC-E0 Addenda Required
UPC-E0 Addenda Separator
UPC-E0 Check Digit
UPC-E0 Number System
UPC-E0 Addenda
UPC-E0 Redundancy
UPC/EAN Addenda Redundancy
EAN/JAN-13 On/Off
Convert UPC-A to EAN-13
EAN/JAN-13 Check Digit
EAN/JAN-13 Addenda
EAN/JAN-13 Addenda Required
EAN-13 Beginning with 2 Addenda Required
EAN-13 Beginning with 290 Addenda Required
EAN-13 Beginning with 378/379 Addenda Required
Default = Don’t Require Addenda
EAN-13 Beginning with 414/419 Addenda Required
EAN-13 Beginning with 434/439 Addenda Required
EAN-13 Beginning with 977 Addenda Required
EAN-13 Beginning with 978 Addenda Required
EAN-13 Beginning with 979 Addenda Required
EAN/JAN-13 Addenda Separator
EAN/JAN-13 Redundancy
Isbn Translate
Convert Isbn to 13-Digit
Issn Translate
Isbn Reformat
Issn Reformat
EAN/JAN-8 On/Off
EAN/JAN-8 Check Digit
EAN/JAN-8 Addenda
EAN/JAN-8 Addenda Required
EAN/JAN-8 Addenda Separator
EAN/JAN-8 Redundancy
MSI On/Off
MSI Check Character
MSI Redundancy
MSI Message Length
Plessey Code
Plessey Code On/Off
Plessey Check Character
Plessey Redundancy
GS1 DataBar Omnidirectional
Plessey Message Length
GS1 DataBar Omnidirectional On/Off
GS1 DataBar Omnidirectional Redundancy
GS1 DataBar Limited
GS1 DataBar Limited On/Off
GS1 DataBar Limited Redundancy
GS1 DataBar Expanded
GS1 DataBar Expanded On/Off
GS1 DataBar Expanded Redundancy
GS1 DataBar Expanded Message Length
Coupon Code Settings
GS1 DataBar Expanded Coupon Preferred Mode
GS1 DataBar Expanded Coupons With AI
GS1 DataBar Expanded Coupons Without AI
Coupon GS1 DataBar Output
In-Store Printed Bar Codes
Stitching
Framing
Redundancy
Trioptic Code
Codablock a
Codablock a On/Off
Codablock a Message Length
Codablock F
Codablock F On/Off
Codablock F Message Length
Minimum Message Length Maximum Message Length Off
GS1 Composite Codes
GS1 Emulation
UPC/EAN Version
GS1 Composite Code Message Length
Default = GS1 Emulation Off
Tcif Linked Code 39 TLC39
QR Code
QR Code On/Off
QR Code Message Length
QR Code Append
Data Matrix
Data Matrix On/Off
Data Matrix Message Length
MaxiCode
Data Matrix Append
MaxiCode On/Off
MaxiCode Message Length
Aztec Code
Aztec Code On/Off
Aztec Code Message Length
Chinese Sensible Han Xin Code
Aztec Append
Han Xin Code On/Off
Han Xin Code Message Length
Maximum Message Length
Page
EAS Settings
EAS Deactivation
EAS Deactivation Zone
EAS Controller Settings
Sensormatic
Checkpoint
Detection Ranges
Programming the EAS Interface
Cable
EAS Controller
EAS Mode of Operation
EAS Interlocked Duration Timeout
EAS Interface
EAS Tag Detection
Interface Keys
Keyboard Function Relationships
Function Code HEX/ASCII Value Full Ascii Ctrl +
Country Codes
Denmark Norway Spain
Supported Interface Keys
IBM PC/AT
Compatibles Apple Mac/iMac
Supported Keys
Page
To Add a Test Code I.D. Prefix to All Symbologies
Utilities
Show Software Revision
Show Data Format
TotalFreedom EZConfig-Scanning Introduction
EZConfig-Scanning Operations
Installing EZConfig-Scanning from the Web
Resetting the Factory Defaults
Scanning
Page
Serial Programming Commands
Menu Command Syntax
Query Commands
Conventions
Examples of Query Commands
Concatenation of Multiple Commands
Responses
Menu Commands
Selection Setting Serial Command
NCR
Paprby
Papglb
Papwnx
KBDCTY60
KBDCTY12
KBDCTY50
KBDCTY19
KBDCTY94
KBDCTY27
KBDCTY24
KBDCTY76
HSTTOA0
HSTTOA1
HSTTOA2
Hstrtn
BELCAN1
BELCAN0
NCR ACK
NCRACK0
PWRMS10
PWRMS11
PWRMS20
PWRMS21
BEPCUR1
BEPCUR3
BEPCUR4
BEPCUR5
HSTDEN0 HSTDEN1
HSTDCH##
Seqblk
Seqdft
SCNSN22
SCNSN23
SCLTYP0
SCLTYP1
HSTXRC0
HSTXRC1
HSTXRC2 CRC HSTXRC3
DLYCHR##
CBRSSX0
CBRSSX1
CBRCK20
CBRCK21
N25DFT
N25ENA0 N25ENA1
C93DFT
C93ENA0 C93ENA1
C11DFT
C11ENA0 C11ENA1
ISBENA0 ISBENA1
Dlycct
ISBUL1##
ISBUL2##
ISBUR1##
ISBUR2##
UPAARQ0
UPAARQ1
UPAADS0
UPAADS1
UPC-E0
Upedft
UPEEN00 UPEEN01
UPEEXP0 UPEEXP1
E13ADS0
E13ADS1
E13ISB0 E13ISB1
E13IBR1
EA8AD20
EA8AD21
EA8AD50
EA8AD51
Rssdft
RSSENA0 RSSENA1
RSSVOT##
Rsldft
Cbfdft
CBFENA0 CBFENA1
CBFMIN####
CBFMAX####
IDMAPP1
IDMAPP0
Maxdft MAXENA1
MAXENA0
DFMBK3?
TSTMNU1
TSTMNU0
Papbio
Page
Product Specifications
Stratos Bioptic Scanner/Scale Product Specifications
Parameter Specification
Depth of Field Charts
Guaranteed Performance
Typical Performance
Standard Connector Pinouts
Host RS232
Host RS485
Host USB Type B
Scale to Host RS232
Scanner to Scale Comm
Scale to Scanner Display
Scale Display
RS232 Auxiliary Scanner Bioptic end
USB Auxiliary Scanner Bioptic end
Page
Maintenance
Maintenance
Troubleshooting a Stratos Bioptic Scanner
Repairs
Diagnostic Indicator
Is the bar code displayed but not entered?
Error Codes
Error Text Description What to do
LASER4ERROR
MOTOR1ERROR
Programerror
Ramerror
Scaleramerror
Scaleromerror
Scalenotype
Page
Product Service and Repair Limited Warranty
Customer Support
Technical Assistance
Page
Reference Charts
Symbology Charts
Linear Symbologies
2D Symbologies
Postal Symbologies
UPC-E1
Ascii Conversion Chart Code
Ctrl +
Lower Ascii Reference Table
Printable Characters
Extended Ascii Characters
Extended Ascii Characters
ISO 2022/ISO 646 Character Replacements
Automatic National Character Replacement ISO/IEC
ISO /IEC 646‐CH
ISO / IEC 646 National Character Replacements
Unicode Key Maps
Key U.S. Style Keyboard
Key European Style Keyboard
Auxiliary Honeywell Scanner Configuration Codes
RS-232
USB Serial
Page
Sample Symbols
Matrix 2
Programming Chart
Save Discard
Reset
Page
Top
Page
Image
Contents