Removing the Bail Sensor
1 | Remove the electronics)enclosure | 5 Note the position of the bail)sensor cable | |
| cover page 6)5. | for reassembly. Incorrect positioning | |
2 | Remove the window page 6)15. | could cause obstruction of the cartridge | |
carriage and motor gears. | |||
|
|
3Remove the center cover page 6)16.
4Remove the right endcover page 6)19.
Bail sensor
6 Disconnect the bail)sensor cable | 8 Unclip the bail sensor from its holder, |
connector from the main PCA, and from | and lift it, with cable, clear of the plotter. |
its ferrite and holding clip on the right |
|
sideplate. | |
The ferrite holder opens from the top. | holder |
| |
| Bail sensor |
|
| ||
| connector |
| |
| Reassembling: The cable goes through |
| |
| the same ferrite as for the windowsensor |
| |
| cable page 624. |
| |
7 | Carefully feed the bail)sensor cable out | Calibration: After having | |
reassembled the plotter, perform | |||
| from the electronics enclosure and from | ||
| the bail calibration chapter 7. | ||
| under the motor assemblies. | ||
|
|
C3187)90000 | RemovalandReplacement 6)55 |