Removing the Front￿Panel Assembly

1Remove the electronics-enclosure cover ' page 6-5.

2Remove the window ' page 6-15.

3 Remove the center cover ' page 6-16.

4Remove the right endcover ' page 6-19.

5Take note of the correct positioning of the front-panel cable for reassembling. Incorrect positioning could cause obstruction of the cartridge carriage or motor gears.

6Unclip the window-sensor cable and front-panel cable from their holding clip on the underside of the front-panel assembly.

Window-sensor

Front-panelcable cable

Clip

7Release the front-panel cable from its clamp on the main PCA, and from its holding clip on the right side of the plotter.

C A U T I O N

Do not force the cable out of its clamp. First pull the clamp gently towards

you to release the cable; then pull the cable easily out of the clamp.

 

Do not release the front￿panel cable from its clamp on the front￿panel PCA￿

Front-panel connector clamp

6-32 Removal￿and￿Replacement

C3187-90000