Errors Indicated by LEDs

Error

The Error LED on the front panel works in combination with the other LEDs to specify the type of error that has occurred. The three possible states of any LED are represented like this:

Off

 

On

 

 

 

 

Flashing

 

 

 

 

 

 

 

 

 

 

 

User Errors

User errors are associated with user settings or user actions and may be solved by the user without calling a Customer Engineer. They are indicated by the Error LED flashing. (Further Information ￿ User's Guide, chapter 4, Troubleshooting.)

Error and Cartridges flashing

Error Cartridges

Possible Causes

Corrective Action

An error was detected during the cartridge4alignment routine.

An error was detected while scanning a setup sheet.

1.Remove the cartridges.

2.Ensure that the protective tape has been removed and that the contacts are clean.

3.Replace the cartridges.

4.If the LEDs do not stop flashing when you lower the window, replace both cartridges with new ones.

See also ￿ later in chapter, w Frequent Cartridge Failure.

1.Check the quality of the media and print of the setup sheet.

2.If the quality appears acceptable, try loading the sheet again face down. If not, use a newly printed setup sheet.

3.If the error persists, perform the setup4sheet calibration.

Error and Ready flashing

Error Ready

Possible Causes

Corrective Action

The current plot is too large for the plotter's memory

To be able to perform this plot, you have to install more memory. (If the plot is a raster plot, it might work if you send it with a no negative motion RTL command.)

C3187490000