Firmware4Code Revision Level
To check the firmware4code revision level that the plotter is using, print a setup sheet or a service configuration plot.
Troubleshooting Tips
Repair + Calibrate
After you have made a repair, consider if any calibrations have been affected.
Print Quality
You can use the user demonstration plot to look at overall print quality including smoothness and straightness of lines, arcs, circles, and characters. The procedure for plotting the demonstration plot is given in the User's Guide.
Diagnosing Problems
You can use the service configuration plot to help diagnose problems. The procedure for plotting the configuration plot is given on page 8423.
Other Tips
On the following pages are tips about solving the following problems:
DServo control4system failures
DFrequent cartridge failure
DBail4lift4mechanism failure
DCartridge carriage rubbing against encoder strip
DPremature wearing of drive belts
DSensor does not find media edge
DLast swath is clipped when replotting
DInk smearing
DPlots joined or not plotted
DIncorrect line widths
DPlotter won't read setup sheet; Plots solid black area fill
DProblems in loading media
C3187490000 | Troubleshooting 8411 |