Setup2Sheet Calibration
This calibration calibrates the power of the LED situated on the cartridge carriage, for better scanning of the setup sheet.
Perform the setup2sheet calibration whenever:
DThe EEROM is cleared
DThe cartridge carriage is replaced
DThe optical sensor on the cartridge carriage is replaced
DProblems frequently occur with setup2sheet scanning
To calibrate the LED, perform the following procedure:
1Enter service mode page 722.
2Load a blank sheet of paper.
o not use vellum, transparent or polyester media, or recycled paper.
3 Hold down the ALT key and press
ALT
Calibration
The plotter positions the cartridge carriage over the media. The carriage remains there for about 1 minute with the red L lit, while the plotter performs the calibration. The plotter then ejects the sheet.
To verify that the calibration has been performed correctly, plot a service configuration plot, page 8223, and look at the field entitled •Setup Sheet LED Calibration formula." A formula appears in this field. If the calibration has not been performed correctly, a message, saying that the LED has not been calibrated for setup sheet, appears.
7210 Calibrations | C3187290000 |