All the part numbers associated with both A.01.00 implementations are obsoleted and replaced by A.01.01 part numbers.

Usage of a DIPB40 ICBextracting tool or similar is highly recommended to prevent damage to the Main PCA traces.

Note that firmware version A.01.01 is available only on EPROMs. Make sure that proper ESD safety procedures are followed and that the devices are correctly plugged into their sockets, leaving the rightmost pair of holes free.

Administrative Information

Classification: Modification recommended

Standards: Labor hours 0.5, Travel authorized

Action Category: On specified failure

Location Category: OnBsite

Service Inventory: Scrap

Used Parts: Scrap

HP Responsible Until: 15BJuneB96

Author/Entity: PP/F900

Problems that will be Corrected by Firmware Release A.01.02

Date:

29 July 1994

Bug Fixing

RTL: Fix bitmap on negative YBcoordinates. (Jail effect)

STARSHIP: PJL enter language = HPGL/2 was going back to HPGL; now goes to HPGL/2.

REPLOT: Replot clips last swath. When doing replot (same size as the original plot), sometimes the last swath of the plot is clipped. This is because the mediaBload sheet length measurement is not exact, so the plotter recognizes the sheet as shorter than it actually is. Fixed by increasing the tolerance on sheet length before clipping by 0.15 in. when replotting. The previous tolerance was only 1/1200 in.

CANCEL: In firmware versions A.01.01 (DesignJet 200) and B.02.00 (DesignJet 220) the user could not cancel while plotting nonBflowBmode plots (plots that don't exceed maximum memory available in plotter). Fixed.

This firmware is not yet available at the time of printing of this manual.

9B8 Product￿History￿and￿Service￿Notes

C3187B90000