When to Calibrate the Plotter
Indications or Repairs Performed | Calibration Required |
|
|
Jagged lines on plots | Cartridge Alignment |
Cartridges are reseated or replaced | Cartridge Alignment |
Drive roller is removed or replaced | Accuracy Calibration |
Media | Accuracy Calibration |
Accuracy Calibration | |
500mm (1mm) |
|
Carriage or carriage LED is removed or replaced | Cartridge Alignment |
| and |
Cartridge Alignment | |
Bail failures occur during media loading | Bail Calibration |
Bail sensor is removed or replaced | Bail Calibration |
Bail Calibration | |
Media sensor is removed or replaced | |
Leading and trailing margins of a plot are greater | |
than 17 mm (0.67 in) |
|
Problems occur scanning a setup sheet. | |
EEROM is cleared or main PCA is replaced | (In this order:) |
| 1. Bail Calibration |
| 2. |
| 3. Cartridge Alignment |
| 4. Accuracy Calibration |
| 5. |
Service Mode
nen ee de
Switch the plotter off.
Align
Cartridges
While holding the Align Cartridges key down, switch the plotter on.
Once the Busy LED lights up, release the Align Cartridges key.
T ! d
T d
i pl Draft, Final, Paper d Transl/Vellum
d P d
7)2 Calibrations | C3187)90000 |