0 When the Ready LED lights up, hold down the SHIFT key and press Accuracy Calib. Read,
The Busy LED lights up. The plotter takes about3 minutes to read the calibration sheet, to calculate the calibration data, and to save the data in the EEROM. During this time, the plotter appears almost motionless for short intervals. The plotter then ejects the sheet.
Unload the sheet. SHIFT
Accuracy
Calib. Read
Bail Calibration
In this procedure, the `up' position of the bail assembly is calibrated. A value is stored in the EEROM when the procedure is completed.
Perform the bail calibration whenever the:DEEROM is clearedDMain PCA is replaced
DBail falls during media loadingDBail switch is replacedDBail3lift mechanism is removed or replacedTo calibrate the bail, perform the following procedure:Enter service mode page 732.Bail Calibration
Hold down the AT key and press Bail Calibration.ALT
The Busy LED lights up and the bail begins cycles of being raised and lowered. During a number of the cycles, the bail is let fall instead of being gently lowered. The calibration ends after about a minute and a half.
738 Calibrations | C3187390000 |