Error and Load Media LEDs lit and steady:Media;path/servo errors.

 

 

LEDs lit

 

 

 

 

and

Error Number and

 

 

 

steady

Description

Corrective Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

82. Shutdown of media axis

See ￿ later in this chapter, w Servo￿Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(X;axis)

System Failures.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22. Shutdown of carriage axis

See ￿ later in this chapter, w Servo￿Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Y;axis)

System Failures.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

86. Carriage;axis failure

Check encoder strip, carriage assembly,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

trailing cable, main PCA.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50. Cartridge;cap failure

See ￿ later in this chapter, w Frequent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cartridge Failure. / Check the service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

station, encoder strip and media motor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

114. Error detected in media;axis

Check media motor, media;motor encoder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

servo feedback loop.

cable, main PCA.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54. Error detected in

Check encoder strip, carriage assembly,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

carriage;axis servo feedback loop.

trailing cable, main PCA.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

118. Bail sensor indicates the bail

See ￿ later in this chapter, w Bail￿Lift￿

 

 

 

 

 

 

 

is up when it should be down or

Mechanism Failure. / Use the bail;sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

vice versa, or the bail drops

test to help troubleshoot. / Check for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

suddenly (missing the notch on

mechanical problems. / Perform the bail

 

 

 

 

 

 

 

the auto cam).

calibration.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

146. Accuracy;calibration error

Did you load the media in the correct

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

orientation? / Ensure that the marks are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

visible on the plot. If not, check cartridges. /

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ensure that the sheet is cut correctly. /

 

 

 

 

 

 

 

 

Perform a cartridge alignment: if alignment

 

 

 

 

 

 

 

 

is correct, the problem may be in the main

 

 

 

 

 

 

 

 

PCA, media motor or media motor gear; if

 

 

 

 

 

 

 

 

alignment is incorrect, the problem may be

 

 

 

 

 

 

 

 

in the carriage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

210. Media;sensor;calibration

Replace the media sensor. If the error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

error. One of the flags on the

persists, there may be a problem with the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

media sensor may be positioned

LED on the cartridge carriage: Perform a

 

 

 

 

 

 

 

too far forward or too far back.

cartridge alignment / Replace LED.

 

 

 

 

 

 

 

 

 

C3187;90000

Troubleshooting 8;9￿