Table
Screen Message | Probable Cause | Recommended Action | |
|
|
|
|
Internal temperature exceeds | 1. | Check that workstation air vents are not | |
| specification. |
| blocked and cooling fan is running. |
|
| 2. | Verify processor speed selection. |
|
| 3. | Replace the processor. |
|
| 4. | Replace the system board. |
|
|
| |
Processor not supported by ROM | Upgrade BIOS to proper version. | ||
Error | BIOS. |
|
|
|
|
| |
The system board does not support | Replace the processor with a compatible one. | ||
Supported | the processor. |
|
|
This BIOS revision does not support | |
Needed for Processor | the installed processor. |
Install the latest BIOS located at http://www.hp.com.
Invalid Electronic Serial | Electronic serial number has | Run Computer Setup. If Setup already has data in |
Number | become corrupted. | the field or will not allow the serial number to be |
|
| entered, download from http://www.hp.com |
|
| and run SP5572.EXE (SNZERO.EXE). |
|
| Run Computer Setup and try to enter serial |
|
| number under Security, System ID, then save |
|
| changes. |
|
|
|
ECC Multiple Bit Error | Chipset has detected more than one | Replace the memory module. |
Detected in Memory Module bad bit in a |
| |
| memory array. |
|
|
|
|
Parity Check 2 | Parity RAM failure. | Run Computer Setup and Diagnostic utilities. |
|
|
|
170 System Diagnostics and Troubleshooting