Intel® IXP45X and Intel® IXP46X Product Line of Network Processors—General Hardware Design Considerations

3.10.1Signal Interface

Table 17.

High-Speed, Serial Interface 0

 

 

 

 

 

 

 

 

 

Input

Pull

 

 

Name

 

Up

Recommendations

 

 

Output

 

 

 

Down

 

 

 

 

 

 

 

 

 

 

 

 

Transmit frame.

HSS_TXFRAME0

 

I/O

Yes

When this interface/signal is enabled and is not being used in a system design, the

 

 

 

 

 

interface/signal should be pulled high with a 10-KΩresistor.

 

 

 

 

 

 

 

 

 

 

 

Transmit data out. Open Drain Output.

HSS_TXDATA0

 

OD

Yes

When this interface/signal is enabled and is either used or not used in a system design,

 

 

 

 

 

the interface/signal should be pulled high with a 10-KΩresistor to VCCP.

 

 

 

 

 

Transmit clock.

HSS_TXCLK0

 

I/O

Yes

When this interface/signal is enabled and is not being used in a system design, the

 

 

 

 

 

interface/signal should be pulled high with a 10-KΩresistor.

 

 

 

 

 

 

 

 

 

 

 

Receive frame.

HSS_RXFRAME0

 

I/O

Yes

When this interface/signal is enabled and is not being used in a system design, the

 

 

 

 

 

interface/signal should be pulled high with a 10-KΩresistor.

 

 

 

 

 

 

 

 

 

 

 

Receive data input.

HSS_RXDATA0

 

I

Yes

When this interface/signal is enabled and is not being used in a system design, the

 

 

 

 

 

interface/signal should be pulled high with a 10-KΩresistor.

 

 

 

 

 

 

 

 

 

 

 

Receive clock.

HSS_RXCLK0

 

I/O

Yes

When this interface/signal is enabled and is not being used in a system design, the

 

 

 

 

 

interface/signal should be pulled high with a 10-KΩresistor.

 

 

 

 

 

 

Notes:

 

 

 

 

 

1.

Features disabled/enabled by Soft Fuse must be done during the boot-up sequence. A feature cannot be enabled after

 

being disabled without asserting a system reset.

2.

Features disabled by a specific part number, do not require pull-ups or pull-downs. Therefore, all pins can be left

 

unconnected.

 

 

3.

Features Enabled by a specific part number — and required to be Soft Fuse-disabled, as stated in Note 1 — only require

 

pull-ups or pull-downs in the clock-input signals.

 

 

 

 

 

 