The lower roller assembly area

To clear the lower roller assembly area (Area C):

1.Open the top cover.

2.Open the right-side access door.

Vertical baffle handle

Baffle plate

Lower roller assembly

3.Remove the imaging guides (not shown in this illustration).

IMPORTANT: Use care when handling the imaging guides. Hold the imaging guides by the green handles only.

4.Turn the vertical baffle handle latch counterclockwise to unlatch the baffle plate. Lower the baffle plate until it stops. This unlocks the lower roller assembly.

5.Grasp the lower roller assembly handle (as shown) and slide the assembly toward the rear of the machine.

6.Remove any documents or document pieces.

IMPORTANT: Do not slide the lower roller assembly back into place without first removing the imaging guides. Failure to remove them first can cause misalignment and/or damage to the machine.

7.Slide the lower roller assembly back into place.

8.Raise the plate into its original position. Turn the vertical baffle latch clockwise to lock the baffle plate into position. Be sure the baffle plate is securely locked into its original position.

9.Replace the imaging guides.

10.Close the right-side access door and top cover.

7-6

A-61092 September 1999

Page 67
Image 67
Kodak A-61092 manual Lower roller assembly area