Kodak A-61092 manual Function Code Name, Description

Models: A-61092

1 118
Download 118 pages 34.53 Kb
Page 30
Image 30
Code

Function code listing Following is a listing of the function codes and descriptions.

Code

F01

F02

F04

F05

F06

F07

F08

F09

F10

F11

F12

F13

F14

F15

F16

Function Code Name

Select Mode

Restore Mode

Counting Only

Accessory Status

Terminate Batch

Level 0

Last Image Address

Total Document Count

Level 0 Count

Level 1 Count

Level 2 Count

Level 3 Count

Reset Level Counts

Alarm Volume

Alarm Tone

Description

Allows you to select one of the predefined application modes. Enter a value from 1 to 18 and press Enter.

Allows you to restore the current application mode to its default status, provided mode overrides are not saved.

Allows you to count the number of documents entering the scanner without scanning. Enter 1 to turn Counting Only on, or 0 to turn Counting Only off and press Enter.

Displays the current status of each accessory installed. Press the Down arrow to view the status of the next accessory, or press the Up arrow to view the status of the previous accessory.

Allows you to prematurely end a batch.

Allows you to define the next document scanned as a Level 0 document.

Allows you to display the image address of the last document scanned.

Allows you to display the total number of documents that entered the feeder (Level 3, Level 2, Level 1 or Level 0). Press 0 to reset the counter and then press Enter.

Allows you to display the total number of documents that have entered the feeder as Level 0 documents. Press 0 to reset the counter and then press Enter.

Allows you to display the total number of documents that have entered the feeder as Level 1 documents. Press 0 to reset the counter and then press Enter.

Allows you to display the total number of documents that have entered the feeder as Level 2 documents. Press 0 to reset the counter and then press Enter.

Allows you to display the total number of documents that have entered the feeder as Level 3 documents. Press 0 to reset the counter and then press Enter.

Allows you to reset all the level counters (Level 0, Level 1, Level 2, and Level 3) to 0.

Allows you to adjust the volume of the alarm. Press the Up arrow to increase the volume or press the Down arrow to decrease the volume, then press Enter.

Allows you to adjust the pitch of the alarm tone. Press the Up arrow to increase the pitch or press the Down arrow to decrease the pitch, then press Enter.

A-61092 September 1999

4-5

Page 30
Image 30
Kodak A-61092 manual Function Code Name, Description