Replacement procedures

Replacing the air filter

Replacement procedures should be performed on an as-needed basis. Components that need periodic replacement include the air filter, exposure lamps and the imaging guides.

The air filter should be replaced at least once a year, more often if needed.

IMPORTANT: Never operate the scanner without an air filter installed. The imaging apparatus will quickly become contaminated with dust and dirt, impairing image quality.

1.Remove the air filter cover by pressing in on the top of the cover to release the catch.

Air filter cover

Catch

Air filter

2.Carefully remove the old air filter. Note the orientation of the filter as it is removed from the machine.

3.Orient a new air filter the same as the old air filter, and insert it into the space left open by the old air filter.

4.Replace the air filter cover by first inserting the bottom edge and then pushing the top edge in place.

5-12

A-61092 September 1999