Reflectance Fields (Grades A through F)

Reflectance Fields (Grades A through F)

Contrast — a comparison of the darkest element and the lightest element of the bar code.

MOD — Modulation. A measure of the consistency of the overall bar code print clarity (all elements), specifically the occurrence of spots (in spaces) and voids (in bars).

DEF — Defect ratio. A measure of the consistency of the individual element print clarity, specifically the occurrence of spots (in spaces) and voids (in bars).

RMIN — Minimum reflectance. A measure of the lightest element of the bar code.

Table 1 illustrates how the dimensional field values are converted to a pass/fail status and the print clarity field values are converted to letter grades:

 

Table 1 — Bar Code Grades

 

 

 

 

 

 

 

 

 

Grade

 

 

 

 

 

 

Field

A (Pass)

B

C

D

W/N

3:1 to 2:1*

 

 

 

 

3:1 to 2.2:1**

 

 

 

F (Fail)

2:1 to 1:1* 2.2:1 to1:1**

NEW

Contrast

MOD

DEF

RMIN

0.080 to 0.010

100 to 70

100 to 70

0 to 15

0 to 49

60 to 55

69 to 60

16 to 20

54 to 40

59 to 50

21 to 25

39 to 20

49 to 40

26 to 30

0.009 to 0.000

19 to 0

39 to 0

31 to 100

50 to 100

*Narrow Element Width greater than or equal to 0.020

**Narrow Element Width less than 0.020