2. System Requirements

2.1Requirements (system recommendations)

We recommend the following software and hardware when using this application (TG-2000A).

Item

Requirement

Recommended

 

 

 

PC

PC/AT interchangeable machine

Operation check completed, using IBM,

 

 

COMPAQ, and DELL

CPU

Pentium III 350 MHz or faster :

Pentium 4 1 . 8GHz or faster

 

within 1000 indoor units

 

 

Pentium III 1 GHz or faster :

 

 

1001 indoor units or over

 

Memory

128 MB or more

256 MB or more

 

 

 

HDD

6 GB or more (2GB or more of C drive free

4GB or more of C drive free space necessary

 

space necessary)

 

Storage device

FDD, CD-ROM drive

Devices other than those shown at the left may

 

 

a l s o b e i n s t a l l e d .

Resolution

1024 × 768 or higher, 65536 colors or more

 

 

 

 

Serial port

1 port or more

Required when using RS-485 communication WHM

LAN

Internal LAN (10/100 Mbps)

*1

OS

Windows XP Professional

English version only

 

Windows 2000 Professional

* Personal computer must support each OS.

 

Service Pack 2 and above

 

Other

Computer must be dedicated for this use (TG-2000A).

*1 Purchase the option, or use the equipment recommended for the personal computer when purchasing the personal computer.

2.2Compatible Units

The TG-2000A has two main functions: air conditioner controller and cost accounting. However, not all functions are available with all air conditioners.

Table: Compatible units and function list

(¡: supported, ￿: Certain restrictions apply, ×: Not supported)

Function

Control/

Charging (Billing)

 

Charging (Billing) with WHM

Model

Maintenance

without WHM

 

 

 

 

 

 

 

 

 

 

 

Y series

¡

 

¡ *1

Super Y series

¡

 

¡ *1

R2 series

¡

 

¡ *1

WR2 series

¡

 

¡ *1

WY series

¡

 

¡ *1

 

 

 

 

Multi S series

¡

 

¡ *1

 

 

 

 

Free plan Indoor unit

¡

 

¡ *1

Free plan LOSSNAY

¡

×

 

￿ (A separate watt hour meter is

 

 

 

 

required . Billing is done with

 

 

 

 

watt-hour units)

LOSSNAY with heating/

¡

×

 

￿ (A separate watt hour meter is

humidifying

 

 

 

required . Billing is done with

 

 

 

 

watt-hour units)

“A” control type

¡

×

 

￿ (A separate watt hour meter is

 

(Adapter required)

 

 

required . Billing is done with

 

 

 

 

watt-hour units)

“K” control type

¡

×

 

￿ (A separate watt hour meter is

 

(Converter required)

 

 

required . Billing is done with

 

 

 

 

watt-hour units)

*1 : Can be calculated for each charging block. May not be available with some older models.

2