Motorola WS5100 Click the Configuration tab, •Collection Settings •Violation Parameters, Radio

Models: WS5100

1 364
Download 364 pages 29.43 Kb
Page 234
Image 234
6-10WS5100 Series Switch System Reference Guide

6-10WS5100 Series Switch System Reference Guide

2.Click the Configuration tab.

The MU Intrusion Detection tab consists of the following two fields:

Collection Settings

Violation Parameters

3.Within the Collection Settings field, set the Detection Window interval (in seconds) the switch uses to scan for MU violations. The available range is from 5 - 300 seconds.

4.Refer to the Violation Parameters field to define threshold values that trigger an alarm:

Violation Type

Displays the name of the violation for which threshold values are set in the mobile unit, radio

 

and switch columns.

Mobile Unit

Set the MU threshold value for each violation type. If exceeded, the MU will be filtered and

 

displayed within the Filtered MUs screen. Set the values appropriately in respect to the

 

number of MUs within the switch managed network and how often they will be associating/

 

disassociating, and having their authentication and encryption credentials verified.

Radio

Set the radio threshold value for each violation type. If exceeded, the MU will be filtered and

 

displayed within the Filtered MUs screen.

Switch

Set the switch’s threshold value for each violation type. If exceeded, the offending MU will

 

be filtered (from the switch) and displayed within the Filtered MUs screen.

Time to Filter

Set the Time to Filter interval (in seconds) the switch uses to filter out MUs that have been

 

defined as committing a violation. Refer to Viewing Filtered MUs on page 6-11to review the

 

contents of the MUs that have been filtered thus far.

CAUTION: Setting mobile unit threshold values too low can jeopardize MU performance

!or break the MU’s connection.

5. Click on Apply button to save the configuration.

Page 234
Image 234
Motorola WS5100 Click the Configuration tab, •Collection Settings •Violation Parameters, or break the MU’s connection