Option | Parameter | Description | Your Setting |
Post Error Pause | Disabled | Specify whether to stop the POST once |
|
| [Enabled] | at the end of POST if an error occurs |
|
|
| during the POST. |
|
Stay Off | Specify the state of power when the AC |
| |
| [Last State] | power to the server is turn off once and |
|
| Power On | then on. |
|
Power On Delay | [0] - 255 | Specify the power on delay time within |
|
Time (Sec) |
| the range between 0 and 255 seconds. |
|
|
| The time specified is valid when "Power |
|
|
| On" or "Last State" is specified for AC |
|
|
| LINK. |
|
Platform Event | [Disabled] | This item becomes meaningless when |
|
Filtering | Enabled | the notification feature of remote |
|
|
| management card (RMC) is enabled. |
|
|
| [ | ]: |
IMPORTANT: To power on the server from the UPS (Uninterruptible
Power Supply), select [Server] - [AC LINK] - [Power On].
The table below shows the operation when the AC power to the server is turn off once and then on again, depending on the setting of "AC LINK."
System status before AC power off | Setting of AC LINK |
| ||
Stay Off | Last State | Power On | ||
| ||||
Operating | Off | On | On | |
Aborting (DC power being off also) | Off | Off | On | |
Forced shutdown | Off | Off | On |