4-20 Configuring Your Server

Running the Utility

To run the utility, perform the following procedures:

1.Power on the server.

The following message appears while POST is in progress.

IMPORTANT: The message appears for each additional SCSI controller.

Adaptec SCSI BIOS Vxxx xxxxx

(c) 2000 Adaptec, Inc. All Rights Reserved

Press <Ctrl> <A> for SCSISelect(TM) Utility!

2.Press and hold Ctrl and A.

The SCSISelect utility starts and its Main menu appears.

3.Select the channel and press Enter.

AIC-7902 A at Slot 23 02:03:00

AIC-7902 B at Slot 23 02:03:01

NOTE: "AIC-7902A" is for backup file devices. "AIC-7902B" is for internal SCSI hard disk drives.

The Options menu appears.

4.Select option in the Options box and press Enter.

AIC-7902 at slot 23, 03:03:00

Would you like to configure the SCSI controller, or run the

SCSI Disk Utilities? Select the option and press <Enter>.

Options

Configure/View SCSI Controller Settings

SCSI Disk Utilities

Enable HostRAID Support

If you wish to configure the adapter or a device, select "Configure/View SCSI Controller Settings".

If you wish to format a disk, verify disk media, or display a list of devices and their SCSI IDs, select "SCSI Disk Utilities".