General Description 2-11

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS LED

Description

Procedure

 

 

indication

 

 

 

 

 

 

 

On (green)

The server is operating normally.

 

 

Flashing

The server is operating with the

Check the AC POWER LED indication

 

 

(green)

 

memory, CPU in degraded state.

on the rear panel of the server.

 

 

 

An uncorrectable memory error

Identify the device in degraded state

 

 

 

 

has often occurred.

by using the BIOS setup utility

 

 

 

 

 

"SETUP," and replace it as soon as

 

 

 

 

 

possible.

 

 

Off

The power is off.

 

 

 

POST is in progress.

Wait for a while. The STATUS LED

 

 

 

 

 

turns green when POST is completed.

 

 

 

A CPU error occurred.

Turn the power off and then turn it on.

 

 

 

A CPU temperature alarm was

If the POST screen displays an error

 

 

 

detected. (IERR)

message, take notes of the message,

 

 

 

 

 

and contact your service

 

 

 

A timeout occurred when the time

 

 

representative.

 

 

 

set for the watchdog timer arrived.

 

 

 

A CPU bus error occurred.

 

 

 

 

A memory dump request is made.

Wait until the memory dump is

 

 

 

 

 

completed.

 

 

On (amber)

A temperature alarm was detected.

Check if the internal fans are clean

 

 

 

 

 

and if the fan units are firmly

 

 

 

 

 

connected.

 

 

 

 

 

If the STATUS LED indication does not

 

 

 

 

 

change when the fans are normal,

 

 

 

 

 

contact your service representative.

 

 

 

A voltage alarm was detected.

Contact your service representative.

 

 

 

All the power supply units failed.

 

 

 

Flashing

Either of the following was detected

Connect the power cord to supply

 

 

(amber)

in the redundant power

power. If the power supply unit is

 

 

 

configuration:

faulty, contact your service

 

 

 

AC power not supplied to one of

representative.

 

 

 

 

the two power supply units

 

 

 

 

Failure of one of the two power

 

 

 

 

 

supply units

 

 

 

 

A fan alarm was detected.

Check if the fan units are firmly

 

 

 

 

 

connected.

 

 

 

 

 

If the STATUS LED indication does not

 

 

 

 

 

change when the fans are normal,

 

 

 

 

 

contact your service representative.

 

 

 

A temperature warning was

Check if the internal fans are clean

 

 

 

detected.

and if the fan units are firmly

 

 

 

 

 

connected.

 

 

 

 

 

If the STATUS LED indication does not

 

 

 

 

 

change when the fans are normal,

 

 

 

 

 

contact your service representative.

 

 

 

A voltage warning was detected.