Error | Error message | Recommended Action | ||
code | ||||
|
|
| ||
02D1 | System Memory exceeds the CPU's caching | Contact your service representative. | ||
| limit. |
|
| |
02F4 | EISA CMOS not write able. |
|
| |
02F5 | DMA Test Failed. |
|
| |
02F6 | Software NMI Failed. |
|
| |
02F7 |
|
| ||
0B22 | Processors are installed out of order. | Request the maintenance to replace the CPU. | ||
0B28 | Unsupported Processor detected on | Make sure that the server supports the CPU. | ||
| Processor 1. | If you are not sure, contact your service | ||
0B29 | Unsupported Processor detected on | representative to request the maintenance. | ||
| Processor 2. |
|
| |
0B30 | FAN1 Alarm occurred. | Contact your service representative to replace | ||
0B31 | FAN2 Alarm occurred. | the fan. |
| |
0B32 | FAN3 Alarm occurred. |
|
| |
0B33 | FAN4 Alarm occurred. |
|
| |
0B34 | FAN5 Alarm occurred. |
|
| |
0B35 | FAN6 Alarm occurred. |
|
| |
0B36 | FAN7 Alarm occurred. |
|
| |
0B37 | FAN8 Alarm occurred. |
|
| |
0B5F | Forced to use Processor with error | Because an error is detected in every CPU, | ||
|
| the system is forcibly started. Contact your | ||
|
| service representative. | ||
0B60 | DIMM group #1 has been disabled | Contact your service representative. | ||
0B61 | DIMM group #2 has been disabled |
|
| |
0B62 | DIMM group #3 has been disabled |
|
| |
0B70 | The error occurred during temperature | Contact your service representative. | ||
| sensor reading. |
|
| |
0B71 | System Temperature out of the range. | Contact your service representative to replace | ||
|
| the fan. |
| |
0B74 | The error occurred during voltage sensor | Contact your service representative. | ||
| reading. |
|
| |
0B75 | System voltage out of the range. |
|
| |
0B80 | BMC Memory Test Failed. | Turn off the power once and then on again to | ||
0B81 | BMC Firmware Code Area CRC check failed. | start the server. | If the error cannot be | |
0B82 | BMC core Hardware failure. | corrected, contact your service representative. | ||
0B83 | BMC 1BF or 0BF check failed. |
|
| |
0B8B | BMC progress check timeout. | Turn off the power once and then on again to | ||
0B8C | BMC command access failed. | start the server. | If the error cannot be | |
|
| corrected, contact your service representative. | ||
0B8D | Could not redirect the console - BMC Busy - | |||
0B8E | Could not redirect the console - BMC Error - |
|
|