Troubleshooting 8-7

 

 

 

 

 

 

 

 

 

 

 

 

Error

Error message

Recommended Action

 

 

code

 

 

 

 

 

 

 

0B8F

Could not redirect the console - BMC

Turn off the power once and then on again to

 

Parameter Error -

start the server.

If the error cannot be

0B90

BMC Platform Information Area corrupted.

corrected, contact your service representative.

0B91

BMC update firmware corrupted.

 

 

 

 

0B92

Internal Use Area of BMC FRU corrupted.

This is not a fatal error.

Turn off the power

 

 

once and then on again to restart the server.

 

 

If the error cannot be corrected, contact your

 

 

service representative.

 

 

0B93

BMC SDR Repository empty.

Turn off the power once and then on again to

 

 

restart the server. If the error cannot be

 

 

corrected, contact your service representative.

0B94

IPMB signal lines do not respond.

This is not a fatal error.

Turn off the power

 

 

once and then on again to restart the server.

 

 

If the error cannot be corrected, contact your

 

 

service representative.

 

 

0B95

BMC FRU device failure.

This is not a fatal error.

Turn off the power

 

 

once and then on again to restart the server.

 

 

If the error cannot be corrected, contact your

 

 

service representative.

 

 

0B96

BMC SDR Repository failure.

Turn off the power once and then on again to

0B97

BMC SEL device failure.

start the server.

If the error cannot be

 

 

corrected, contact your service representative.

0B98

BMC RAM test error.

0B99

BMC Fatal hardware error.

 

 

 

 

0B9A

Management controller not responding.

Update the RMC firmware. If the error cannot

 

 

be corrected, contact your service

 

 

representative.

 

 

 

0B9B

Private I2C bus not responding.

Turn off the power once and then on again to

0B9C

BMC internal exception.

start the server.

If the error cannot be

0B9D

BMC A/D timeout error.

corrected, contact your service representative.

0B9E

SDR repository corrupt.

 

 

 

 

0B9F

SEL corrupt.

 

 

 

 

0BB0

SMBIOS – SROM data read error.

Contact your service representative.

0BB1

SMBIOS – SROM data checksum bad.

 

 

 

 

8100

Memory Error detected in DIMM group #1.

Contact your service representative to replace

8101

Memory Error detected in DIMM group #2.

the DIMM in the relevant group.

8102

Memory Error detected in DIMM group #3.

 

 

 

 

None

Expansion ROM not initialized – PCI Mass

Disable initialization of the optional device

 

Storage Controller in slot n (n: slot number)

expansion ROM by using the BIOS SETUP

 

 

utility (see Chapter 4).

 

 

 

H/W Configuration of BMC is corrupted.

Use the NEC EXPRESSBUILDER to

 

!! Update BMC F/W Configuration by

configure the remote management card (see

 

configuration tool !!

Chapter 6).

 

 

 

 

!! Refer to BMC configuration manual !!