4-22 Configuring Your Server

„SCSI Device Configuration

Move the cursor onto "SCSI Device Configuration" and press Enter to display the submenu.

The following table lists submenu items, available parameters, and descriptions.

IMPORTANT: Select a parameter for each submenu item on a per- SCSI ID basis. Verify the SCSI ID of a desired device before configuration.

NOTE: To find out the SCSI ID for the optional device connected, select "SCSI Disk Utilities" on the Options menu and press Enter. See "SCSI Disk Utilities" for detail.

Submenu item

Parameter

Description

 

 

Sync Transfer Rate

[320]

33.3

Select "320".

 

 

(MB/Sec)

160

20.0

You may need to change the value

 

80.0

10.4

depending on your optional device.

 

66.6

ASYN

Refer to the manual that comes with your

 

40.0

 

optional device for details.

 

 

Packetized

[Yes]

 

Optimizes bus utilization and minimizes

 

No

 

command overhead to bolster performance

 

 

 

by transferring commands, data, and status

 

 

 

using Deal Transition (DT) data phases.

QAS

[Yes]

 

Quick Arbitration and Selection (QAS)

 

No

 

reduces the overhead of control release on

 

 

 

the SCSI bus from one device to another to

 

 

 

help decrease command overhead and

 

 

 

increase bus utilization.

 

 

Initiate Wide

[Yes]

 

Select "Yes" if your SCSI device supports the

Negotiation

No

 

Wide SCSI interface. Select "No" if not.

Enable Disconnection

[Yes]

 

Select "Yes".

 

 

 

No

 

 

 

 

Send Start Unit

[Yes]

 

Select "Yes" to send the command to the

Command

No

 

hard disk drive. Otherwise select "No".

BIOS Multiple LUN

Yes

 

Select "No".

 

 

Support

[No]

 

 

 

 

Include in BIOS Scan

[Yes]

 

Select "Yes".

 

 

 

No

 

 

 

 

 

 

 

[

]: Factory-set