Upgrading Your Server
Disk array configuration of internal hard disk drives Observe the following notes on configuring a disk array:
–The server must contain more than one SCSI or SAS hard disk drive having the same capacity and the same rotational speed. (The minimum number of required disks depends on the configuration of RAID (Redundant Arrays of Inexpensive [Independent] Disks).)
–Select/set a RAID level "RAID0", "RAID1", or "RAID5" of disk array configuration.
When installing a system in an internal hard disk drive, you should use "Express Setup" to perform all the procedures for RAID configuration, OS installation, and then OS setup.
Use Express Setup even when not installing a system. Start Express Setup, select [OS Selection] → [Others]. The installer automatically performs all the procedures for RAID configuration, maintenance partition setting, and then maintenance utility installation.
When making the setup in manual mode, use the RAID configuration utility in the chip on the board. You can start the utility during execution of POST that automatically starts immediately after you turn on the server power switch. For details, see the online document in the NEC EXPRESSBUILDER