5I/F time-out between printer and optional tray (ERROR 81) .

Is an optional tray (2nd / 3rd tray or envelope feeder) used?

Yes

Is the connection between the Main board and the optional tray connected

 

 

properly. (See Chapter 7.1.)

 

 

No

Connect the cable properly.

 

 

 

 

Yes

Replace the Main board.

 

 

 

 

• Is the printer recovered?

 

 

No

Isolate the trouble by following the 2nd/ 3rd tray or multi feeder

 

 

 

 

maintenance manual. (See Appendix C or D.)

YES

END

 

 

Replace the Main board.

• No

6I/F time-out between printer and Duplex Unit (ERROR 83)

Is an Duplex Unit used?

Yes

Is the connection between the Main board and the Duplex Unit connected

 

 

properly. (See Chapter 7.1.)

 

 

No

Connect the cable properly.

 

 

 

 

Yes

Replace the Main board.

 

 

 

 

• Is the printer recovered?

 

 

No

Isolate the trouble by following the Duplex Unit maintenance manual.

 

 

 

 

(See appendix C.)

YES

END

 

 

Replace the Main board.

• No

7I/F time-out occurs between the printer and the operator panel (ERROR 80) .

Is the connecting cord of the operator panel connected to the PANEL connector of the Main board properly? (See Chapter 7.1.)

No

• Yes

Connect the connecting cord of the operating panel to the PANEL connector of the Main board properly.

Is the connecting cord defective?

Yes

Replace the connecting cord.

 

 

No

Replace the operator panel assembly.

 

 

• Is the printer recovered?

No

Replace the Main board.

YES

END

40930701TH DRAFT Vesion

150 /

Page 131
Image 131
Oki 24DX manual F time-out between printer and optional tray Error, F time-out between printer and Duplex Unit Error, 150