5I/F time-out between printer and optional tray (ERROR 81) .
•Is an optional tray (2nd / 3rd tray or envelope feeder) used?
• | Yes | Is the connection between the Main board and the optional tray connected | ||
|
| properly. (See Chapter 7.1.) | ||
|
| • | No | Connect the cable properly. |
▼ |
|
|
|
|
• | Yes | Replace the Main board. | ||
▼ |
|
|
|
|
• Is the printer recovered? | ||||
|
| • | No | Isolate the trouble by following the 2nd/ 3rd tray or multi feeder |
|
|
|
| maintenance manual. (See Appendix C or D.) |
▼ | YES | END |
| |
• |
| |||
▼ | Replace the Main board. | |||
• No |
6I/F time-out between printer and Duplex Unit (ERROR 83)
•Is an Duplex Unit used?
• | Yes | Is the connection between the Main board and the Duplex Unit connected | ||
|
| properly. (See Chapter 7.1.) | ||
|
| • | No | Connect the cable properly. |
▼ |
|
|
|
|
• | Yes | Replace the Main board. | ||
▼ |
|
|
|
|
• Is the printer recovered? | ||||
|
| • | No | Isolate the trouble by following the Duplex Unit maintenance manual. |
|
|
|
| (See appendix C.) |
▼ | YES | END |
| |
• |
| |||
▼ | Replace the Main board. | |||
• No |
7I/F
•Is the connecting cord of the operator panel connected to the PANEL connector of the Main board properly? (See Chapter 7.1.)
•No
▼
• Yes
Connect the connecting cord of the operating panel to the PANEL connector of the Main board properly.
Is the connecting cord defective?
• | Yes | Replace the connecting cord. |
▼ |
|
|
• | No | Replace the operator panel assembly. |
▼ |
|
|
• Is the printer recovered? | ||
• | No | Replace the Main board. |
▼ | YES | END |
• |
40930701TH DRAFT Vesion | 150 / |