6)Timing charts

■ Compatible mode

a) Data receiving timing

PARALLEL DATA

 

 

(DATA BITs 1 to 8)

 

 

0.5 ∝s min.

 

0.5 ∝s min.

0.5

∝s min.

 

DATA STOROBE

 

 

0.5 ∝s min.

 

 

0.5 ∝s max.

 

0 min.

 

 

BUSY

 

 

0 min.

 

0 min.

ACKNOWLEDGE

 

 

0.5 ∝s to 10 ∝s

 

 

0 min.

b) On-line → off-line switching timing by ON-LINE SW

ON-LINE SW

BUSY

SELECT

100 ms max.

c) Off-line → on-line switching timing by ON-LINE SW

ON-LINE SW

BUSY

SELECT ACKNOWLEDGE

100 ms max.

0.5 ∝s to 10 ∝s

0 min.

40930701TH DRAFT Vesion