6)Timing charts
■ Compatible mode
a) Data receiving timing
PARALLEL DATA |
|
| |
(DATA BITs 1 to 8) |
|
| |
0.5 ∝s min. |
| 0.5 ∝s min. | |
0.5 | ∝s min. | ||
| |||
DATA STOROBE |
|
| |
0.5 ∝s min. |
|
| |
0.5 ∝s max. |
| 0 min. | |
|
| ||
BUSY |
|
| |
0 min. |
| 0 min. | |
ACKNOWLEDGE |
|
| |
0.5 ∝s to 10 ∝s |
|
|
0 min.
b) On-line → off-line switching timing by ON-LINE SW
BUSY
SELECT
100 ms max.
c) Off-line → on-line switching timing by ON-LINE SW
BUSY
SELECT ACKNOWLEDGE
100 ms max.
0.5 ∝s to 10 ∝s
0 min.
40930701TH DRAFT Vesion | 187 / |