3.3.2Contact Assy

(1)Open the stacker assy 1 and unscrew 2 screw 2 to remove the assy -side (L)3.

(2)Unscrew 2 screws 4 and remove the plate (contact) 5 and contact Assy 6. Note! Don’t deform the electrode plates of the contact assy 6.

2

1

3

Unlock this part before removing 6

6

5

4

40930701TH DRAFT Vesion