3.3.22EP lock shaft
(1)Turn the AC power switch off. Unplug the AC power cord from the outlet.
(2)Remove
(3)Remove screw 1. Turn EP lock lever (L) Assy 2 in the direction of arrow A .
(4)Remove spring 3.
(5)Drop EP lock shaft 4 down and turn in the direction of arrows B and remove it.
4
A B
1 3
2
40930701TH DRAFT Vesion | 81 / |