3.3.22EP lock shaft

(1)Turn the AC power switch off. Unplug the AC power cord from the outlet.

(2)Remove Frame-Main [See.3.3.12(7)]

(3)Remove screw 1. Turn EP lock lever (L) Assy 2 in the direction of arrow A .

(4)Remove spring 3.

(5)Drop EP lock shaft 4 down and turn in the direction of arrows B and remove it.

4

A B

1 3

2