(7)Fusing
After the end of the transfer, the unfused toner image is fused on the paper under heat and pressure as it passes between the heater roller and the
A thermistor which is in contact with the heater roller regulates the heater roller at a predetermined temperature (about 180 ~ 200°C). A safety thermostat cuts off voltage supply to the heater by opening the thermostat in the event of abnormal temperature rises.
The
Heater
Separation Claw | Thermistor |
Heater Roller
Paper
Pressure Spring