3.3.12Motor
(1)Remove the stacker assy. [See 3.3.6]
(2)Remove the feeder
(At this point, the manual feed assy has not to be removed.)
(3)Remove the DC fan motor. [See 3.3.3]
(4)Remove the contact assy. [See 3.3.2]
(5)Remove the
(6)Remove the TR gear 2 and roller transfer 3.(Use
(7)Unscrew 7 screws 4 and remove the main frame 5.
(8)Unlock latches at two points of the lever back up release 6 and pull out it in right direction.
(9)Unhook the EP lock spring 7 and remove the EP lock lever 8.
(10)Take off the E ring 9 and remove the
(11)Unlock 2 latches to remove the motor
(12)Unscrew 2 screws D and remove the motor